[*][2] – System Troubles (continued):
[4] - FTC Trouble (Failure To Communicate)
This trouble condition is generated when the control panel fails to report a signal to the central
station
[5] – Wireless Device/Detector Fault or DEOL Zone Fault
A zone fault condition is generated due to any of the following:
Wireless - If a wireless device fails to report a status or supervisory signal within the wireless
supervisory window (Zone, Keypad or Siren)
DEOL (Double End Of Line) - If a short circuit is detected.
[6] - Wireless Device/Detector Tamper or DEOL Zone Tamper
A zone tamper condition is generated due to any of the following:
Wireless - If the tamper on a wireless device is violated (Zone, Keypad or Siren)
DEOL (Double End Of Line) - If a open circuit is detected
[7] - Wireless Device Low Battery Trouble
This trouble is generated when a low battery condition is detected on a wireless device
[8] - Loss of Time/Date Trouble
This trouble condition is generated when the internal clock (time/date) needs to be reset due to a
loss of power (AC/DC)
Note: pressing [*] with this trouble is displayed will automatically take the user to time/date
programming
For GS2065 and TL265GS trouble conditions, please refer to the respective installation manuals