Programming Navigation
Navigating through programming is simple and intuitive. To enter Installer programming:
Step 1 – Enter [*][8] + [Installer Code]
The default installer code is [5555]
Step 2 – Enter the required 3-digit installer programming section (‘Enter Section’ will be displayed)
At this point, you have the option of choosing the desired programming method:
Section Number Programming
Quick Enroll
Template programming
Section Number Programming:
This is the traditional method of programming and allows the user to enter any programming section.
When using this method, there are two types of programming sections:
Toggle Sections
Data Sections
Toggle Section:
Toggle sections consist of a series of options that may be enabled or disabled. To toggle an option ON or
OFF, press the key number corresponding to the option.
Option Enabled Option Disabled
To exit a toggle section, press [#]
Data Section:
Data sections require multiple 2 or 3 digit number entries. Data sections allow for both decimal or
hexadecimal entries (some data sections have fixed values where the available entries are provided from a
chart. For example ‘Zone Definitions’). To enter hexadecimal data, first enter [*] followed by [1] to [6] to
enter [A] to [F] respectively. To exit hexadecimal programming, enter [*] again.
To exit a data section, either complete all entries or press [#]
Once you exit a programming section, a new 3-digit section may be entered