Serial Numbers:
PC9155:
The PC9155 requires that all device/detector are programmed with an 8-digit serial number.
Wireless Devices:
1 – Way Devices: the serial number for these devices are 6-digits in length. Since the PC9155 requires
that serial number are programmed with 8-digits, enter ‘00’ prior to entering the 6-digit number.
2 – Way Devices: these devices are 8-digits
Wireless Supervision
Supervisory Signal:
Each wireless device automatically transmits a supervisory signal every 64 minutes. This signal is
automatic and contains the following information:
Contact State
Tamper State
Battery Voltage
Supervisory Window:
This is a programmable window in the PC9155 control panel (default = 24 hours). It is required that at
least one supervisory signal be received by the PC9155 from each device/detector before the end of
each supervisory window. If a signal is not received, a Zone Fault trouble condition is generated for the
failed device/detector
Wireless Detector Compatibility
1 – Way Detectors:
1-way 433MHz detectors are compatible with the PC9155
2 – Way Detectors:
2-way 433MHz detectors (contain a prefix ‘WT’) are only compatible with the PC9155 and are NOT
compatible with 1-way receivers
List of 1-way receivers:
PC5132-433
RF5132-433
RF5108-433
SCW9045/47
RFK55XX-433