PC9155 Wireless Alarm Panel
6-1
6 Testing & Troubleshooting
6.1 Wireless Device Placement Test
See sections 2.4 and 2.5
6.2 Testing the System
Inform the monitoring station when beginning or ending alarm system testing.
It is the user’s responsibility to test the alarm system weekly (excluding smoke detectors). Ensure that all the steps in the two tests
below are followed.
Power up system
Program options as required (See programming section)
•Violate, then restore zones
Verify correct Reporting Codes are sent to the central station
Step
1
Siren and Display Test:
This test activates all display pixels and indicator lights and does a four second check
of the siren.
1. Press [Master Code] .
2. The following occurs:
• The alarm system activates the bell output on medium volume for 2 seconds followed
by full volume alarm for 2 seconds. All display lights and LCD pixels t
urn ON.
• The Ready, Armed, Trouble and Power LEDs flash for the duration of the test.
3. To exit the function menu, press .
Step
2
Walk Test:
Walk Test mode allows operation of each detector in the alarm system to be tested.
While in Walk Test mode, the Ready, Armed, and Trouble LED's flash to indicate that
the walk test is active. The walk test can be terminated at anytime by re-entering
[Master code] on the keypad. The alarm system automatically
terminates the walk test on completion. It will annunciate with an audible
warning (5 beeps every 10 seconds), beginning five minutes before the termination of the test.
1. Before testing, ensure that the alarm system is disarmed and the Ready light is on.
2. Press and close all zones to return the alarm system to the ready state.
3. Perform an alarm system test by following the steps in the previous section.
4. Press [M
aster code] to initiate the walk test.
5. To test the zones, activate each detector in turn (e.g., open each door/window or walk in motion detector areas).
When each zone (detector) is activated, the alarm system displaysSecure System Before Arming < >”, or “Secure or
Arm System”, depending on the zone type and the siren will sound for 2 seconds. Use the keys to view
which zones are open. The message disappears when a
ll of the zones are closed.
,
System is
Ready to Arm <>
,
Secure S
y
stem
Before Arming <>
Secure or
Arm S
y
stem <>
,